Neogel A400TL-923 Isophthalic Gelcoat
Neogel A400TL-923 is an AOC non-pre-accelerated, thixotropic isophthalic (ISO) gelcoat. The manufacturer identifies boatbuilding, swimming pools, sanitary ware and transportation as intended markets. The brush grade can be applied by brush or roller. The product data sheet describes good air release, water and weather resistance, including resistance to blistering.
Typical Base Gelcoat Specifications
| Property | Typical value | Test method |
|---|---|---|
| Appearance | Transparent thixotropic liquid | TM 2265 |
| Viscosity at 25 °C, spindle #4, 2 rpm | 26,000–45,000 mPa·s | TM 5042 |
| Viscosity at 25 °C, spindle #4, 20 rpm | 6,500–10,000 mPa·s | TM 5042 |
| Gel time at 25 °C | 12–20 min | TM 2245 |
The viscosity values describe the base gelcoat under two different spindle speeds. Compare each range with measurements taken under the same method and speed. The gel time comes from the laboratory conditions in the manufacturer’s product data sheet. Confirm working time in a representative trial using the intended mold, application method and shop conditions before setting a production schedule.
Typical Cured Base Resin Properties
| Property | Typical value | Test method |
|---|---|---|
| Tensile strength | 90 MPa | ISO 527-2 |
| Tensile modulus | 3,700 MPa | ISO 527-2 |
| Elongation at break | 4.6% | ISO 527-2 |
| Heat deflection temperature | 93 °C | ISO 75A |
The cured base resin figures are typical test results. The specimens were cured for 24 hours at room temperature and post-cured for 24 hours at 80 °C. Use these results for comparisons with equivalent specimens and test conditions. The thermal figure characterizes the test specimen; the finished part should be evaluated against its own laminate design, service conditions and acceptance criteria.
Selecting Neogel A400TL-923 for Brush or Roller Application
For a boat component, swimming pool shell, sanitary part or transportation panel, tell the technical team how the part will be made and what conditions it will see in service. Include the expected exposure to water, outdoor weather or cleaning agents, as applicable. For a new program, evaluate a representative panel with the intended backing laminate and mold surface.
When reviewing a finish sample, agree on the color reference, inspection lighting and visible surface requirements. The PDS describes availability in a range of colors and mentions a paraffinated brush variant on request. Identify the exact finish and variant you need when asking for a quote. Confirm the grade on the sample or container label before starting a trial.
For marine orders requiring classification approval, the manufacturer PDS references CCS approval. Request the current certificate before specifying the product and verify that the grade, manufacturing site, scope and validity match the project requirements. A project-specific specification may also call for additional testing of the gelcoat and backing laminate together.
Storage, Documentation and Quote Requests
The manufacturer lists a typical stability period of three months from dispatch when the original package remains closed and is stored at no more than 20 °C, away from direct sunlight and heat. Use the current safety data sheet and label for storage, handling and transport requirements. Ask for the dispatch date or remaining shelf life when scheduling a time-sensitive order.
Use the complete Neogel A400TL-923 designation when requesting a quote, sample or technical data sheet. Include the intended application, brush or roller process, color reference, quantity, delivery destination and requested delivery date. Confirm the available pack size and any lot documentation at quotation, especially if your receiving specification requires a certificate.
For related grades, compare options in the AOC resin and Neogel gelcoat range. Refer to the AOC product brand overview for manufacturer context. Technical values on this page are based on the English Neogel A400TL-923 PDS, version 1.0.