Synolite 5001-W-903 is an AOC halogen-free fire-retardant unsaturated polyester resin. The manufacturer describes the resin as pre-accelerated, thixotropic and filled, and identifies hand lay-up and filament winding as suitable fabrication methods. Listed applications include building, construction and transportation components requiring fire performance. Specify the complete laminate and its test requirements when discussing a project.

Synolite 5001-W-903 Product Specifications
| Property | Value | Test method |
|---|---|---|
| Appearance | Beige | TM 2265 |
| Solids content, infrared drying | 70–76% | TM 2033 |
| Viscosity at 23 °C, shear rate 250 s⁻¹ | 200–300 mPa·s | TM 2313 |
| Gel time, 25 to 35 °C | 20–40 min | TM 2625 |
| Density at 23 °C | 1,620 kg/m³ | TM 2160 |
The viscosity result for Synolite 5001-W-903 uses a Physica MC1+/Z2 arrangement at the stated temperature and shear rate. The gel-time figure is a laboratory result under the cure-system conditions in the PDS. Compare material measurements under equivalent methods, and confirm the practical working window for the actual reinforcement, part geometry and shop conditions.
Synolite 5001-W-903 for Fire-Performance Applications
The supplied PDS describes fire-retardant, low-smoke and low-toxicity performance for components made with this material. Its approval section cites EN45545-2 HL2/R1 with a glass-fiber content of about 40%. Request the current supporting report and confirm its scope against the required laminate construction, thickness, reinforcement and end use before specifying the system.
For a transportation project, include the required test level and the proposed component construction in the technical enquiry. For a building application, identify the applicable project test and the complete panel or part design. Use reports and qualification results that match the intended construction when reviewing whether the finished component meets its specification.
4 Checks Before Selecting Synolite 5001-W-903
1. Define the finished laminate. Specify the reinforcement, glass content, thickness, surface layers and fabrication method. Include the part geometry and any processing constraints. Keep the approved construction with the product qualification records.
2. Confirm the fire-test evidence. Request the full report required for the project and check the specimen construction and test scope. If the proposed laminate differs, ask the technical team what further qualification is needed before production approval.
3. Review formulation and processing. The PDS advises thorough mixing and avoiding styrene dilution to maintain fire-retardant properties. Request current guidance for the selected process and agree on how the trial will be documented. Record any formulation changes for review.
4. Establish receiving criteria. Specify the tests and units needed on a certificate of analysis, if required. Compare viscosity using the stated method and confirm the gel-time test conditions. Keep typical product data separate from agreed acceptance limits for individual lots.
Processing Trials with Synolite 5001-W-903
For hand lay-up, make a representative trial using the intended reinforcement, mould and surface system. For filament winding, describe the reinforcement and resin application method. Record the trial conditions so the team can assess wet-out, handling and cure consistency. Qualify the resulting laminate for the required mechanical and fire-performance criteria.
The resin is a filled, pre-accelerated system according to the manufacturer PDS. Confirm conditioning, mixing and cure guidance with the technical team before a production trial. Use the same formulation and documented manufacturing conditions as the accepted sample when assessing repeat production.
Synolite 5001-W-903 Supplier and TDS Requests
When contacting a Synolite 5001-W-903 supplier, provide the full AOC grade designation, application, required tests and proposed laminate design. Include quantity, delivery destination and target date. Confirm the available packaging and lots, and request the current Synolite 5001-W-903 TDS, SDS and applicable performance reports.
The supplied PDS lists three months of typical stability without initiator at 25 °C in dark storage. Confirm remaining shelf life for the offered batch and follow the current SDS and label for handling, storage and transport. For repeat orders, provide the previous purchase and lot reference to help match the approved material.
Browse the AOC resin range and the manufacturer’s product brand overview for related materials. This overview uses the English PDS, version 1.0 dated 18 December 2020. Obtain current manufacturer documentation when agreeing on a purchase or project specification.